Top Spring Multi-Functional Water System MX-25

Summary of Shanghai CDC Official Test Data and Experimental Results

Background of Testing

Our company formally entered the Mainland China market in 2012 and initiated the import permit application for Top Spring products early that year. This application required passing rigorous testing by the "Institute for Environmental Health and Related Product Safety" under the Chinese Center for Disease Control and Prevention (CDC). The stringency of their review standards is considered comparable to the international NSF certification system.

Following a high-standard inspection process, Top Spring successfully passed the comprehensive audit on October 1, 2012, and officially obtained the import license, fully demonstrating the product's exceptional safety and quality.

Notably, in the water environment of Shanghai with a total hardness as high as 243 mg/L, the Top Spring system continued to effectively treat water and met both local and international drinking water sanitary standards, proving its superior purification performance and stable quality.

Core Test Conclusions

1

Within a rated water output of 4.00m³ at a flow rate of 2.00L/min, the filtered water quality fully complies with the "Sanitary Standard for Drinking Water".

2

Removal rates for oxygen consumption, volatility phenols, chloroform, and carbon tetrachloride are excellent, far exceeding the 80% standard required by hygiene regulations.

Full Analysis Test Results (Physical and Chemical Indicators)
Test Item Unit Unfiltered After Filtration (Avg) Standard Req. Result
ColorDegree<5<5≤ 15Pass
TurbidityNTU0.290.27≤ 1Pass
pH Value/7.927.986.5 ~ 8.5Pass
Total Hardnessmg/L243241≤ 450Pass
Oxygen Consumptionmg/L0.670.54≤ 3Pass
Total Dissolved Solidsmg/L358355≤ 1000Pass
Al/Fe/Mn/Cu/Znmg/LBelow LimitsNot DetectedCompliantPass
Sulfate/Chloridemg/LBelow LimitsNormal Range≤ 250Pass
Hazardous Substance Removal Rate (Spiked Testing)

* Testing simulates adding high-concentration pollutants to verify the ultimate filtration capacity of the filter.

Chloroform Avg Removal Rate
99.7%
(Required ≥ 80%)
Carbon Tetrachloride Avg Removal Rate
99.7%
(Required ≥ 80%)
Volatile Phenols Avg Removal Rate
95.4%
(Required ≥ 80%)
Oxygen Consumption Avg Removal Rate
74.5%
(Required ≥ 25%)
Water Silver Stability
Cumulative Output Before (mg/L) After (mg/L)
0 m³ (Startup)<0.0010.0012
2.00 m³<0.0010.0012
4.00 m³ (Finish)<0.0010.0011
Microbiological Indicators
Test Item Result Sanitary Standard
Aerobic Plate Count0 ~ 2 CFU/mL≤ 100
Coliform BacteriaNot DetectedAbsent
Escherichia coliNot DetectedAbsent
24-Hour Soaking Safety Test
Test Item Unit Soaking Water Value Requirement (Increment)
Lead (Pb)mg/L< 0.0005≤ 0.001
Cadmium (Cd)mg/L< 0.0001≤ 0.0005
Chromium (Hexavalent)mg/L< 0.004≤ 0.005
Mercury (Hg)mg/L< 0.00005≤ 0.0002
Arsenic (As)mg/L< 0.0005≤ 0.001